1.Brief introduction
Fixed carbon dioxide gas detector measures CO2 leak concentration in open environment. Normally is fixed on the wall to monitor co2 gas leak in real-time. The fixed co2 detector adapts high-quality co2 sensor.in normal air co2 keeps around 0.08%vol,when gas leakage or in case of poor air quality the data reading get higher, until 0.2% or even 0.5%vol the co2 detector will make alarms to remind people to take measurements or leave away immediately.
The CO2 sensor adopts the NDIR infrared absorption detection principle, and the microprocessor performs signal acquisition, processing and output, realizes ambient temperature compensation, corrects the nonlinear relationship in principle, and has the unique characteristics of NDIR products, such as good selectivity, high sensitivity, no oxygen dependence, and long life.Digital co2 sensors already have processing electronics integrated, possibly with automatic calibration capabilities
2.Features
(1). High Accuracy with NDIR sensor for co2 detector to ensure precise measurements.
(2). Audible and flashing alarms when CO2 exceed safe thresholds.
(3). IP 65 water dust proof to ensure works normally in outdoor ambient.
(4). With passive relay support drive external fan or solenoid valve,or remote alarm lamp.
(5). Infrared remote control support operation remotely
3.Technical parameters
|
Product name |
Fixed carbon dioxide gas detector |
|
Product Size: |
144*190*87mm |
|
Product weight: |
1130g |
|
Detect Gas: |
CO2 |
|
Measure range: |
0-5%VOL or customized range |
|
Resolution: |
0.01%VOL |
|
Response time: |
≤40s |
|
Working voltage: |
DC24V |
|
Output signal: |
4-20 mA or RS485 Modbus RTU |
|
Options function: |
With audible & visual alarm need $15/pc |
|
Connection: |
3 wires or 4 wires |
|
Transmission cables: |
Shielded cable 3 x 1.5 mm2 or 4*1.5mm2 |
|
Features: |
With passive relay output signal,N/O relay |
|
Temperature range: |
- 20 ℃ ~ 50 ℃ |
|
Humidity |
15%-90%(RH) |
|
Certificate: |
CE,ATEX,ISO9001 |
|
Explosion-proof marks: |
Exib II CT6 |
|
IP class: |
IP65 water dust proof |
|
Transmission distance: |
<1000 m |
4.About CO2 Gas Safe Standard.
For carbon dioxide detector detection range 0-5%vol:
Safety range: According to international standards (such as OSHA), the CO₂ concentration in workplaces must be lower than 0.5%vol (5000ppm), and the short-term exposure limit should <1%vol.
Low alarm point: 0.5%vol (warning ventilation or checking the source of leakage).
High alarm point: 1%vol (immediate evacuation and initiation of emergency measures).
Danger point: 3%vol or more can cause shortness of breath and confusion.
5.Maintenance
Regularly calibrate the carbon dioxide gas detector once a year in order to monitor correctly CO2 concentration in air; Clean the dirt on the sensor of the CO2 detector.
6. Contact Us
E-mail: lucy@huafankj.com WhatsApp/Wechat: +0086 15702973573
Hot Tags: carbon dioxide gas detector, China carbon dioxide gas detector manufacturers, suppliers